Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Yonsei Medical Journal ; : 505-511, 2016.
Artigo em Inglês | WPRIM | ID: wpr-21002

RESUMO

PURPOSE: During cardiopulmonary resuscitation (CPR), chest compression (CC) depth is influenced by the surface on which the patient is placed. We hypothesized that training healthcare providers to perform a CC depth of 6-7 cm (instead of 5-6 cm) on a manikin placed on a mattress during CPR in the hospital might improve their proper CC depth. MATERIALS AND METHODS: This prospective randomised controlled study involved 66 premedical students without CPR training. The control group was trained to use a CC depth of 5-6 cm (G 5-6), while the experimental group was taught to use a CC depth of 6-7 cm (G 6-7) with a manikin on the floor. All participants performed CCs for 2 min on a manikin that was placed on a bed 1 hour and then again 4 weeks after the training without a feedback. The parameters of CC quality (depth, rate, % of accurate depth) were assessed and compared between the 2 groups. RESULTS: Four students were excluded due to loss to follow-up and recording errors, and data of 62 were analysed. CC depth and % of accurate depth were significantly higher among students in the G 6-7 than G 5-6 both 1 hour and 4 weeks after the training (p0.05). CONCLUSION: Training healthcare providers to perform a CC depth of 6-7 cm could improve quality CC depth when performing CCs on patients who are placed on a mattress during CPR in a hospital setting.


Assuntos
Adulto , Feminino , Humanos , Masculino , Leitos , Reanimação Cardiopulmonar/educação , Pessoal de Saúde/educação , Hospitais , Manequins , Pressão , Estudos Prospectivos , Estudantes de Medicina , Tórax/fisiologia
2.
Journal of Korean Medical Science ; : 315-319, 2013.
Artigo em Inglês | WPRIM | ID: wpr-25341

RESUMO

No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins lying on 4 different surfaces using a visual feedback system. The surfaces were as follows: A, a bed frame; B, a deflated air mattress placed on top of a foam mattress laid on a bed frame; C, a typical air mattress configuration with an inflated air mattress placed on a foam mattress laid on a bed frame; and D, C with a backboard. Deflation of the air mattress decreased MCD significantly (B; 14.74 +/- 1.36 vs C; 30.16 +/- 3.96, P < 0.001). The use of a backboard also decreased MCD (C; 30.16 +/- 3.96 vs D; 25.46 +/- 2.89, P = 0.002). However, deflation of the air mattress decreased MCD more than use of a backboard (B; 14.74 +/- 1.36 vs D; 25.46 +/- 2.89, P = 0.002). The use of a both a backboard and a deflated air mattress in this configuration reduces MCD and thus helps achieve accurate CC depth during cardiopulmonary resuscitation.


Assuntos
Humanos , Leitos , Reanimação Cardiopulmonar/instrumentação , Força Compressiva , Desenho de Equipamento , Massagem Cardíaca/instrumentação , Unidades de Terapia Intensiva , Manequins , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA